Ionizing Blower Selection Chart

Series Balance Decay Rate 1000v to 100v (per ESD S3.1) Coverage Cubic Feet Per Minute Heater Emitter Cleaner Ion Output
Elimstat Micro    0 +/- 10 volts   < 4 seconds at 12" 1' x 3' Area Two Speed
(21-42 CFM)
No No Steady State DC
Elimstat Benchtop     0 +/- 3 volts   1 second at 12" 1' x 5' Area Three Speed
(50-75-100 CFM)
No No Steady State DC
Elimstat Overhead    0 +/- 15 volts   1 second at 12" 3' x 5' Area Variable Speed
(230-450 CFM)
No Yes Inherent Balance AC
Elimstat VSE 3000     0 +/- 5 volts   < 2 seconds at 12" 3' x 6' Area Variable Speed
(80-160 CFM)
Yes No Inherent Balance AC
Elimstat High Output VSE 3000     0 +/- 5 volts  < 2 seconds at 12" 3' x 6' Area Variable Speed
(100-255 CFM)
Yes No Inherent Balance AC
Simco-Ion™ Bench Top     0 +/- 5 volts  < 2 seconds at 12" 1' x 5' Area Variable Speed
(35-70 CFM)
Yes Yes Inherent Balance AC
Simco-Ion™ Wide Coverage Bench Top     0 +/- 5 volts  1 second at 12" 2' x 4' Area Three Speed
(70-95-120 CFM)
Yes Yes Inherent Balance AC
Simco-Ion™ Overhead     0 +/- 5 volts  1.5 seconds at 12" 3' x 5' Area Variable Speed
(150-300 CFM)
Yes Yes Inherent Balance AC